Power supply | 230 V~ ( +6% -10%) - 50 Hz |
---|---|
Absorbed power | 10 W |
Motor max. load | 800 W |
Accessories max. load | 0,5 A |
Electric lock max. load | 15 VA |
Operating temperature | -20°C ÷ +55°C |
Protection fuses | 2 |
Function logics | Semi-automatic Automatic Safety devices "Stepped" semi-automatic "Stepped" automatic "Stepped" Safety devices Semi-automatic B Dead-man C |
Opening/closing time | Programmable (from 0 to 120 s) |
Pause time | Programmable (from 0 to 4 min.) |
Closing leaf delay | Programmable (from 0 to 4 min.) |
Opening leaf delay | 2 s (can be excluded) |
Thrust force | Adjustable on 50 levels for each motor |
Terminal board inputs | Open Open free leaf Stop Limit-switch Opening safety devices Closing safety devices Power supply + Earth |
Terminal board outputs | Flashing lamp Motors 24 Vdc accessories power supply 24 Vdc indicator-light Fail safe 12 Vac electric lock power supply |
Programmable functions | Logic Pause time Thrust Force Torque at initial thrust Opening and closing leaf delay Reversing stroke Over-pushing stroke indicator light Pre-flashing Electric lock Fail safe Safety devices logic |
Learning function | Simple or complete work time learning, with or without Limit-switch and/or Gatecoder. |